From: "John Powers" <john_powers@oaisys.com>
We have been using the "DX" API (not the Global Call API) on Dialogic T1s for years without issue, on both versions 5.x and 6.x of the Dialogic DNA. We performed testing on a D/240JCT-T1 and no problems were observed when idle or when 1 port was being utilized. When multiple ports were in play, many DTT1_OOF errors were raised, which would clear out, but then reoccur. With the exact same setup, this did not occur when using the D/240SC-T1 board. I only have access to a single sample of the JCT board (expensive), but I have been able to replicate these symptoms with the same board in multiple systems and with multiple provider interfaces. I suspect this particular board, but Intel has "tested" this board three times and claims no errors. At this point I think there is either something wrong with this particular board (which I am unable to verify) or the entire model of board is somehow different than the SC version. Can anyone provide illumination?
-